node-logix
Nodejs package to handle PLC as Micro800 of Allen Bradley or Logix
Features
-
Promise response with bluebird
-
Manager multiple connections to write/read tags using pooling with generic-pool
-
Listener events as connect, connect_error, disconnect, closing, or found, found_error (discover function)
-
Ardunio mode: functions as digitalRead, digitalWrite, analogWrite, analogRead, digitalOutRead and analogOutRead
-
Autoclose EIP Socket session
-
Enable or disable identity on connect (ignoreIdentity param in connect function)
-
Support to write and read string or array
-
Support typescript
-
Support Micro800
Install package
npm install node-logix
or
yarn add node-logix
Protocol
- EtherNet/IP
Example with events, read and write tags
const PLC = ; const comm = "192.168.100.9"; comm; comm; comm;
Example: Discover devices
Find devices using dgram socket
const PLC = ; PLC;
Example: Arduino mode
comm ;0 1 2 3 4 5 6;
Default Options
PLCdefaultOptions = allowHalfOpen: true // Socket option nodejs, keep open TCP socket Micro800: false // use path for Micro800 port: 44818 // default port EIP connectTimeout: 3000 arduinoMode: true // Enable Arduino functions only Micro800 pool: // options generic-pool min: 0 max: 3 Promise : Bluebird //bluebird priorityRange: 2 fifo: false testOnBorrow: true evictionRunIntervalMillis: 17000 idleTimeoutMillis: 30000
- ArduinoMode only working with Micro800 enable, to working with other PLC, yout must be create custom pinMapping JSON and replacePin function:
commpinMapping = digital: output: "_IO_EM_DO_{dd}" input: "_IO_EM_DI_{dd}" analog: input: "_IO_EM_AI_{dd}" output: "_IO_EM_AO_{dd}" ;/** * @description replace pin mapping * @param * @param * @param */ { if typeof str !== "string" throw "Pin must be a string not a " + typeof str; if typeof pin === "string" && !/\d{1,}/ throw "Pin must has number to assing pin value: " + pin; const match = str; if match === null throw `Replace: no match with {d} or {dd}`; if matchindex > 0 return str; return str;}
More Examples
NOTE:
Connection size:
-
Packets have a ~500 byte limit, so you have to be cautions about not exceeding that or the read will fail. It's a little difficult to predict how many bytes your reads will take up becuase the send packet will depend on the length of the tag name and the reply will depened on the data type. Strings are a lot longer than DINT's for example.
-
Micro800 has CIP protocol Limited, check examples to check work functions
Inpired by projects
TODO
- Unit testing